  • Comb Generator, 10 MHz to 50 GHz

    U9391F - Keysight Technologies

    The Keysight Technologies, Inc. U9391F comb generators were developed to provide precision phase calibration, for non-linear measurements using the PNA-X nonlinear vector network analyser (NVNA), referenced to the National Institute of Standards and Technology (NIST) standard. Additionally, the comb generators can be used to calibrate PNA and PNA-X network analyzers for phase and delay measurements of frequency converters without requiring reference or calibration mixers.

  • Comb Generator, 10 MHz to 67 GHz

    U9391G - Keysight Technologies

    The Keysight Technologies, Inc. U9391G comb generators were developed to provide precision phase calibration, for non-linear measurements using the PNA-X nonlinear vector network analyser (NVNA), referenced to the National Institute of Standards and Technology (NIST) standard. Additionally, the comb generators can be used to calibrate PNA and PNA-X network analyzers for phase and delay measurements of frequency converters without requiring reference or calibration mixers.

  • synchro or resolver to digital (BCD) converters

    AIT - Computer Conversions Corporation

    The TSb series are miniature, high performance continuous tracking synchro or resolver to digital (BCD) converters and angle indicators employing a type 2 servo loop, designed for military and industrial control applications. They will accept any 3 wire synchro or 4 wire resolver input over a frequency range of 50 to 1200Hz. and convert it into 0 to 359.9 degrees or +/-179.9 degrees, TTL compatible BCD data.

  • Synchro to BCD and Resolver to BCD Converters

    TSBC TRBC - Computer Conversions Corporation

    The TSB Series are miniature, high performance, continuous tracking, synchro or resolver to digital (BCD) converters and angle indicators employing a type 2 servo loop, designed for military and industrial control applications. They will accept any 3 wire synchro or 4 wire resolver input over a frequency range of 50 to 1200Hz. and convert it into 0 to 359.9 degrees or +/-179.9 degrees, TTL compatible BCD data.

  • Automatic Voltage Regulator – 1.5kVA To 3kVA

    SVR Pro - Falcon Electric, Inc

    *Convenient Rackmount/Tower Design*UL Listed for 55°C Operation in Harsh Environments*True Sinewave Output*Superior Power Conditioning*Wide Input Voltage Window*Precision Output Voltage Regulation*Superior Brownout, Surge & Transient Protection*Frequency Converter Option*Battery Backup Capability Option*LCD Display with Advanced Monitoring for Easy Remote Management*RS-232C, USB & Optional SNMP/HTTP Agent

  • Automatic Voltage Regulator – 1kVA to 3kVA

    SVR-PL™ Series - Falcon Electric, Inc

    *Convenient Rackmount/Tower Design*UL Listed for High Temperature Operation -30°C to +65°C (-22°F to +149°F)*True Sinewave Output*Input Power Factor Correction*Wide Input Voltage Window*Precision Output Voltage Regulation*Extended Brownout, Plus Surge & Transient Protection*Frequency Converter Option*High Temperature LED Display*RS-232C, USB & Optional SNMP/HTTP Agent

  • MMW Downconverters

    Innovative Technical Systems

    Innovative Technical Systems has designed numerous microwave and millimeter-wave downconverters for a variety of applications. Typical downconverters include balanced mixers, phase-locked local oscillators, LO multipliers, and output IF amplifiers. RF LNAs are also provided for many downconverters up to 100 GHz.These downconverters can be designed for numerous communications, radar, and instrumentation applications. We will customize these converters for frequency coverage ,noise figure, gain, and mechanical form-factor.

  • Torque Instrument

    Vetek Weighing AB

    DTR is a microprocessor based digital indicator, totally autonomousand with input for strain gauge based torque transducers.A ≤±0,02% accuracy makes it possible to be used use in qualitysystems as first or second line sample, periodically calibrated by aSIT center. Measuring system consists of a particularly long-termstable analogue section, of a carrier frequency amplifier whichminimises thermal drifts and of a 16 bits A/D converter whichensures 65.000 internal divisions.

  • Digital Down-Conversion Firmware

    FW2DDC - Teledyne SP Devices

    FW2DDC equips ADQ7WB and ADQ7DC with real-time functions commonly used in radio frequency (RF) receivers. It also contains the proprietary ADX technology which corrects mismatch errors in time-interleaved analog-to-digital converters (TI-ADCs) and thereby ensure industry-leading spurious-free dynamic range (SFDR). The digital signal processing also helps reduce the data rate to a manageable level in order to simplify data post-processing and storage.

  • Intelligent A/D I/O Unit

    RAD242 - Acces I/O Products, Inc.

    Model RAD242 is an intelligent, two-differential-channel, 24-bit analog-input interface unit that includes a Delta-Sigma A/D converter. The converter has a digital output filter with adjustable notch frequency from 10 Hz to 2000 Hz. The pod also has 13 bits of digital input/output. A precision 10 VDC voltage that can be used for transducer excitation is available at connector pin 5. As much as 60 mA current can be provided. It is packaged in a NEMA 4 enclosure for remote installation in harsh environments. RAD242 also provides a user-definable interrupt input and counter/timer input. An optional RAD Firmware Development Kit is available if you wish to use those user-programmable input lines or to develop a custom program.

  • Clamp Meter, Auto, True RMS, 400 A AC, 600 V AC, 600 V DC, 28 mm Jaw Opening Max.

    72-7226 CAL - Tenma

    The 72-7226 CAL from Tenma is a digital clamp meter. This stable, safe and reliable digital clamp multimeter is designed with large scale integrated circuits and A/D converter as the core as well as overload protection and novel structure which make them a superb tool for electricians. It measures AC/DC voltage, AC/DC current, frequency, duty cycle, resistance, diodes and continuity and also includes data hold, sleep mode and relative mode features. The resistance measurement range from 400 ohm/4kohm/40Kohm/400Kohm/4Mohm/40Mohm (±(1%+2)), frequency measurement range from 10Hz to 10MHz (±(0.1%+3) accuracy). It is 3 3/4 digit digital clamp meter with precise operation, fashionable structure and highly reliable measuring instrument. The meter uses large scale of integrated circuit with double integrated A/D converter as its core and has full range overload protection. It complies with IEC61010, pollution degree 2, overvoltage category (CAT II 600V, CAT III 300V) and double insulation.

  • Clamp Meter, Auto, True RMS, 400 A AC, 600 V AC, 600 V DC, 28 mm Jaw Opening Max.

    72-7226 CAL DU - Tenma

    The 72-7226 CAL DU from Tenma is a digital clamp meter. This stable, safe and reliable digital clamp multimeter is designed with large scale integrated circuits and A/D converter as the core as well as overload protection and novel structure which make them a superb tool for electricians. It measures AC/DC voltage, AC/DC current, frequency, duty cycle, resistance, diodes and continuity and also includes data hold, sleep mode and relative mode features. The resistance measurement range from 400 ohm/4kohm/40Kohm/400Kohm/4Mohm/40Mohm (±(1%+2)), frequency measurement range from 10Hz to 10MHz (±(0.1%+3) accuracy). It is 3 3/4 digit digital clamp meter with precise operation, fashionable structure and highly reliable measuring instrument. The meter uses large scale of integrated circuit with double integrated A/D converter as its core and has full range overload protection. It complies with IEC61010, pollution degree 2, overvoltage category (CAT II 600V, CAT III 300V) and double insulation.

  • Clamp Meter, Auto, True RMS, 400 A AC, 600 V AC, 600 V DC, 28 mm Jaw Opening Max.

    72-7226 CAL D - Tenma

    The 72-7226 CAL D from Tenma is a digital clamp meter. This stable, safe and reliable digital clamp multimeter is designed with large scale integrated circuits and A/D converter as the core as well as overload protection and novel structure which make them a superb tool for electricians. It measures AC/DC voltage, AC/DC current, frequency, duty cycle, resistance, diodes and continuity and also includes data hold, sleep mode and relative mode features. The resistance measurement range from 400 ohm/4kohm/40Kohm/400Kohm/4Mohm/40Mohm (±(1%+2)), frequency measurement range from 10Hz to 10MHz (±(0.1%+3) accuracy). It is 3 3/4 digit digital clamp meter with precise operation, fashionable structure and highly reliable measuring instrument. The meter uses large scale of integrated circuit with double integrated A/D converter as its core and has full range overload protection. It complies with IEC61010, pollution degree 2, overvoltage category (CAT II 600V, CAT III 300V) and double insulation.

  • Spectrum Analysis, Up To 70 GHz

    S930907B - Keysight Technologies

    The S930907B spectrum analysis (SA) adds high-performance microwave spectrum analysis to the N522xB/N524xB PNA family up to 70 GHz. With fast stepped-FFT sweeps resulting from optimized data processing, the SA application provides quick spurious searches over broad frequency ranges. Simultaneous spectrum measurements can be done using up to five test and reference receivers. This multi-channel SA can be used with the internal swept-signal generators for efficient measurements of spurious signals emanating from mixers and frequency converters. The SA application employs source-power and receiver-response calibration as well as fixture de-embedding, providing in-fixture and on-wafer spectrum measurements with the highest level of accuracy.

  • Spectrum Analysis, Up To 26.5 GHz

    S930902B - Keysight Technologies

    The S930902B spectrum analysis adds high-performance microwave spectrum analysis to the PNA family up to 26.5 GHz. With fast stepped-FFT sweeps resulting from optimized data processing, the SA application provides quick spurious searches over broad frequency ranges. Simultaneous spectrum measurements can be done using up to five test and reference receivers. This multi-channel SA can be used with the internal swept-signal generators for efficient measurements of spurious signals emanating from mixers and frequency converters. The SA application employs source-power and receiver-response calibration as well as fixture de-embedding, providing in-fixture and on-wafer spectrum measurements with the highest level of accuracy.